A Study in the Application of Capacitive Techniques to the Measure of the Flow Velocity of a Two Phase Slurry

Loading...
Thumbnail Image

Authors

Fenstermacher, Max E.

Issue Date

1977

Type

Thesis

Language

en_US

Keywords

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

Capacitance methods can be applied to electrically measure mass flow of slurries in pipes. The mass flow relation is Q(kg/sec)=v(m/sec)·density(kg/m3)·pipe cross-sectional area (m2). A capacitive instrument designed with electrodes large (relative to pipe diameter) for density measurements and small for velocity measurements, was fabricated and tested. Preliminary calculations and tests showed that the capacity of the large electrode is related to the average density and to the difference in dielectric constants of simple two component slurry mixtures in the pipe. This study, which concentrated on the velocity electrodes, indicates that measurement of mean velocity u can be accomplished using two electrodes with known separation L by cross correlating the signals obtained from them. Local fluctuations (bubbles or vortices) in the density of the material flowing through the pipe which persist during the time to transit both electrodes (∆t=L/u) provide the signals which can be correlated to obtain the transit delay time At. Then the mean velocity u=L/ ∆t. Reproducibility of the ∆t determination depends on the signal-to-noise ratio. In principle, capacitive instruments which combine density and velocity measurements can be produced commercially and used in applications for which continuous measurement of mass flow of a slurry mixture in a pipe is required.

Description

x, 79 p.

Citation

Publisher

License

U.S. copyright laws protect this material. Commercial use or distribution of this material is not permitted without prior written permission of the copyright holder. All rights reserved.

Journal

Volume

Issue

PubMed ID

DOI

ISSN

EISSN